Disclaimer: All products are for laboratory research only and not for human or animal use or consumption. For in-vitro research by qualified professionals only

Sealed AICAR 50mg research vial on a grey ground, labeled for laboratory research use only

AICAR Peptide: Why AICAR Is a Nucleoside Analog and Not a Peptide at All

The AICAR nucleoside analog is not a peptide, and clearing that up is the most useful thing this page can do. In particular, AICAR is 5-aminoimidazole-4-carboxamide ribonucleoside, a nucleoside analog: a small molecule built from a modified base joined to a ribose sugar. It is not a chain of amino acids, so by definition it is not a peptide. Suppliers also catalog and list it alongside peptides, which is why the phrase exists at all. For laboratory work the catalog lists AICAR for in vitro research. Finally, the chemistry is not a pedantic point. A nucleoside and a peptide behave differently in solution, in storage, and on the certificate that proves what is in the vial.

CAS number: 2627-69-2 (PubChem CID 17513), the nucleoside also called acadesine. In particular, that is the PubChem identity used on this page.

All material discussed on this page is for laboratory research use only. It is not for human or animal consumption, and nothing here describes use in a person.

The AICAR nucleoside analog in brief

Short version

  • Identity: 5-aminoimidazole-4-carboxamide ribonucleoside, also written as AICA riboside and also called acadesine. Specifically, a nucleoside analog, structurally related to adenosine.
  • What it is not: a peptide. There are no amino acids and no peptide bonds in the molecule.
  • Why the name sticks: it sits in the same research catalogs as peptides. However, catalog position and chemical class are two different things.
  • What happens in cells: equilibrative nucleoside transporters carry it in, and the cell then phosphorylates it to a monophosphate called ZMP.
  • What ZMP does: it mimics AMP at the regulatory sites of AMP-activated protein kinase, activating the kinase without shifting cellular ATP, ADP or AMP.
  • Caveat: it also competes with adenosine for the nucleoside transporter, so not every measured effect is an AMPK effect.
  • Handling: the instincts a researcher builds around peptides, proteases and adsorption do not transfer straight across to a small molecule.
  • Out of scope here: anything written about this compound in a person. None of that material appears below.

What the AICAR nucleoside analog actually is

A nucleoside is, in particular, a base joined to a sugar. The AICAR nucleoside analog is an imidazole carboxamide base joined to ribose. The full chemical name, 5-aminoimidazole-4-carboxamide-1-beta-D-ribofuranoside, simply describes those two parts and how they are connected.

A peptide is, in contrast, a different kind of object. It is a sequence of amino acids joined by peptide bonds. That sequence governs almost everything a lab does with one: how it folds, which enzymes cut it, and how it sticks to glass and plastic.

Property AICAR A research peptide
Molecular class Namely a nucleoside analog, a small molecule In contrast, a chain of amino acids
Building blocks Specifically, one modified base plus one ribose sugar Amino acid residues, from a handful to dozens
Bond that defines it A glycosidic bond between base and sugar Instead, peptide bonds between residues
Has a sequence No, it does not Yes, and the sequence is the identity
Vulnerable to proteases No, because there are no peptide bonds Yes, and this is the usual stability problem
Identity confirmed by Specifically, small molecule methods: HPLC purity, mass, NMR or IR In contrast, sequence and mass: HPLC purity plus mass spectrometry, often sequencing
The AICAR nucleoside analog against a peptide, side by side. In particular, the two columns almost never share a row, which is the point.

So why is it searched for as a peptide, then? Because research suppliers group products by what researchers study, not by molecular class. AICAR sits next to mitochondrial peptides and growth factor fragments because the questions people ask about it sit in the same corner of cell biology. If a project needs a genuine peptide in that area for comparison, our MOTS-c research listing carries one. The label on the shelf changed. However, the chemistry never did.

How this nucleoside analog enters cells and becomes ZMP

On its own, the AICAR nucleoside analog does very little to a kinase. Inside the cell, enzymes make the active species. It then crosses the cell membrane through equilibrative nucleoside transporters, the same carriers that handle adenosine. Once inside, the cell phosphorylates it to its monophosphate derivative, ZMP. Corton and colleagues characterized this in rat hepatocytes in 1995, where incubation with AICAR led to accumulation of ZMP inside the cell (Corton and colleagues, 1995).

The transporter step is not, in fact, a detail. When researchers inhibited equilibrative nucleoside transport in rat brain slices, AICAR activation of the kinase fell sharply (Gadalla and colleagues, 2004). Where that transporter is scarce or blocked, the compound reaching the outside of the cell is not the compound doing the work.

What ZMP does at AMPK

AMP-activated protein kinase is, in particular, a cellular energy sensor. When energy status falls, it increases activity and expression of proteins involved in catabolism and switches off biosynthetic pathways (Hardie and colleagues, 2012). AMP is the signal it reads.

ZMP is close enough in shape to AMP to be read as AMP, in fact. In particular, the 1995 hepatocyte work reported that ZMP mimics both of AMP’s activating effects on the kinase: direct allosteric activation, and phosphorylation by the upstream kinase. The useful part for an experimentalist is what it does not do. Unlike fructose loading or heat shock, the existing ways of activating the kinase in intact cells, AICAR did not perturb cellular ATP, ADP or AMP. That is why it became a standard laboratory tool. It pulls the lever without rearranging the room.

The same work then traced the downstream chain in hepatocytes. First the kinase showed activation. Then a known target showed phosphorylation and inactivation. Finally, two of the pathways that target controls, fatty acid and sterol synthesis, almost stopped.

What the in vitro and animal literature reports

Everything in the table below is a cell or animal measurement, and this page labels it as such. None of it describes an outcome in a person. In addition, the AICAR nucleoside analog results here stay inside those systems.

System What was measured Reported result
Hepatocytes from rats, in vitro Intracellular ZMP In particular, it accumulated after incubation with AICAR
The same hepatocyte system, in vitro ATP, ADP and AMP contents However, not perturbed
Those hepatocytes again, in vitro Fatty acid and sterol synthesis Almost total cessation
Isolated rat adipocytes, in vitro Kinase activity Activated in a time and concentration dependent manner
The same adipocyte system, in vitro Lipogenesis, and phosphorylation of acetyl-CoA carboxylase Lipogenesis inhibited, and phosphorylation increased
Adipocytes after preincubation, in vitro Response to the lipolytic agent isoprenaline Reduced after preincubation
White and red rat muscle, four week animal study Citrate synthase, succinate dehydrogenase, malate dehydrogenase Activities increased in white quadriceps and soleus, not in red quadriceps
The same muscle study Hexokinase and GLUT-4 Hexokinase increased in all three muscles, and GLUT-4 increased in red and white quadriceps
Rat cerebrocortical brain slices, in vitro Kinase activation with nucleoside transport inhibited Greatly attenuated, in fact
Reported measurements in cells and in animals. Sources are the four studies listed in the references. In particular, the muscle tissue results are from the rat study and are not extended beyond it.

The adipocyte results come, in particular, from a 1994 study in isolated rat cells (Sullivan and colleagues, 1994). The muscle tissue measurements come from a four week study in rats (Winder and colleagues, 2000). Both are animal data. Neither says anything about a person, and this page does not extend them.

Where selectivity breaks down

The 2004 brain slice study also found something that should change how an AICAR experiment is designed. Alongside activating the kinase, AICAR competed with adenosine for uptake by the nucleoside transporter. The consequence is a rise in extracellular adenosine and activation of adenosine receptors, a separate mechanism from kinase activation. The authors stated it plainly. Researchers should use caution in ascribing an effect of AICAR to kinase activation, especially where inhibition of adenosine re-uptake has consequences of its own.

That makes the AICAR nucleoside analog a good tool with a known second mode of action, not a clean one. Two practical points follow.

  • Regard kinase activation as a hypothesis in your system, not a given. Measure it. A phenotype plus a label reading AMPK activator is not evidence of kinase involvement.
  • Control for adenosine signalling where it could matter. An adenosine receptor antagonist is how the 2004 authors separated the two mechanisms.

Why this nucleoside analog needs different handling from a peptide

Most laboratory habits around research peptides exist because peptides are fragile in specific ways. A nucleoside is fragile in different ways, or not at all. Therefore the AICAR nucleoside analog should not inherit peptide-handling rules by default.

Concern Peptide AICAR
Proteolytic enzymes The central stability problem for short peptides Not applicable, because there are no peptide bonds to cut
Adsorption to glass and plastic A real loss route, especially at low concentrations Much less of a concern for a small polar molecule
Solvent Often aqueous buffer, sometimes with a co-solvent for difficult sequences A polar small molecule; follow the solubility stated on the documentation for the lot
Freeze-thaw cycling Repeated cycles are a known risk to structure Still avoid repeated cycling of a made-up solution, but the failure mode is not loss of fold
What degradation looks like Cleavage products, aggregation, loss of activity with structure intact Chemical breakdown of the base or the sugar linkage
Storage Sealed at the condition on the label and certificate Similarly, sealed at the condition on the label and certificate
The handling differences follow from the chemistry. In particular, the last row is the one thing that does not change.

One principle, however, holds for both. Keep the sealed container at the condition printed on its label and certificate, and avoid repeated freeze-thaw cycles once a laboratory has made a solution. Our guide to peptide stability in research formulations covers why that matters for amino acid chains specifically. That is a quick way to see which concerns carry over to a nucleoside and which do not.

Analytical identity: what the certificate should confirm

This is where the peptide and nucleoside distinction stops being academic and starts affecting what a researcher should ask for. For a peptide, identity means the sequence. A certificate that proves purity but never establishes which sequence is present has proved the wrong thing. For a small molecule like AICAR there is no sequence to confirm, so identity rests on the molecular structure instead.

Certificate checks for the AICAR nucleoside analog

Line on the certificate For a peptide For AICAR as a small molecule
Identity Sequence confirmed, usually by mass and often by sequencing Structure confirmed, by mass plus a structural method such as NMR or IR
Purity HPLC purity, with the method stated HPLC purity, with the method stated, similarly
Mass Expected against the sequence mass Expected against the molecular formula, instead
Water content Often relevant for lyophilized peptide powder Also relevant for a lyophilized or crystalline solid
Matching the lot The lot number on the certificate matches the vial Similarly, the lot number on the certificate matches the vial
Appearance and solubility Stated Stated as well
What identity evidence looks like for each class. The purity line is the same. In contrast, the identity line is not.

Two checks apply to any lot, whatever its class, then. Match the lot number on the vial to the certificate before anything goes into an assay. Then read the method next to each result rather than only the number. Our walkthrough on reading lab testing and certificates of analysis goes line by line through what each entry should tell you.

What this page does not cover

Writers discuss AICAR far more often outside a laboratory context than inside one. None of that material appears here in any form. What this page does carry is the molecular chemistry, the uptake and conversion step, the pathway pharmacology of the kinase, in vitro and animal measurements labeled as such, and the documentation question. In short, the AICAR nucleoside analog discussion stays in the laboratory.

Research material

AICAR for in vitro research. Supplied for laboratory research use only, with certificates of analysis published in our COA library.

Related reading: Lab Tested Peptides in the USA; AOD 9604 Peptide

References

Uptake and kinase papers

  1. Corton JM, Gillespie JG, Hawley SA, Hardie DG, European Journal of Biochemistry, 1995;229(2):558-565, PMID 7744080, https://pubmed.ncbi.nlm.nih.gov/7744080/. In particular, this page cites this paper for AICAR uptake into rat hepatocytes, accumulation of ZMP, ZMP mimicking both activating effects of AMP on the kinase, ATP, ADP and AMP contents not being perturbed, phosphorylation and inactivation of a known kinase target, and the near cessation of fatty acid and sterol synthesis.
  2. Gadalla AE, Pearson T, Currie AJ, Dale N, Hawley SA, Sheehan M, Hirst W, Michel AD, Randall A, Hardie DG, Frenguelli BG, Journal of Neurochemistry, 2004;88(5):1272-1282, PMID 15009683, https://pubmed.ncbi.nlm.nih.gov/15009683/. In particular, this page cites this paper for attenuation of kinase activation by equilibrative nucleoside transport inhibitors in rat cerebrocortical slices, competition with adenosine for the nucleoside transporter, the resulting rise in extracellular adenosine and adenosine receptor activation, and the authors’ caution about ascribing effects to kinase activation.
  3. Hardie DG, Ross FA, Hawley SA, Nature Reviews Molecular Cell Biology, 2012;13(4):251-262, PMID 22436748, https://pubmed.ncbi.nlm.nih.gov/22436748/. In particular, this page cites this paper for the description of AMP-activated protein kinase as a cellular energy sensor that increases catabolic protein activity and expression while switching off biosynthetic pathways when energy status falls.

Adipocyte and muscle papers

  1. Sullivan JE, Brocklehurst KJ, Marley AE, Carey F, Carling D, Beri RK, FEBS Letters, 1994;353(1):33-36, PMID 7926017, https://pubmed.ncbi.nlm.nih.gov/7926017/. In particular, this page cites this paper for the isolated rat adipocyte results: time and concentration dependent kinase activation, inhibition of lipogenesis with increased phosphorylation of acetyl-CoA carboxylase, and the reduced response to isoprenaline after preincubation.
  2. Winder WW, Holmes BF, Rubink DS, Jensen EB, Chen M, Holloszy JO, Journal of Applied Physiology, 2000;88(6):2219-2226, PMID 10846039, https://pubmed.ncbi.nlm.nih.gov/10846039/. In particular, this page cites this paper for the four week rat study measurements: citrate synthase, succinate dehydrogenase and malate dehydrogenase activities in white quadriceps and soleus but not red quadriceps, and the hexokinase and GLUT-4 results by muscle type.

Frequently asked questions

Identity questions on the AICAR nucleoside analog

Is acadesine the same compound?

Yes. Acadesine, AICA riboside and AICAR are three names for the same nucleoside. In particular, the literature uses all three, and searching only one of them will miss a substantial part of the published record. Therefore, when cross-referencing a supplier listing against a paper, check which name the paper used before concluding the compounds differ.

My cells showed little response. What are the candidate explanations?

Three, before anyone doubts the compound itself. Firstly, the system may carry little nucleoside transport activity, in which case the material never reaches the inside of the cell in quantity. Secondly, the conversion step may be limiting even where uptake is adequate. Alternatively, the readout may be measuring something downstream of a branch point the pathway did not take in that system. Each is testable, and a positive control with a direct activator separates them.

Handling and scope questions

Does it need the same storage handling as a peptide?

Not identically. The failure routes differ. In particular, a peptide chain is vulnerable to proteolysis and to interface-driven aggregation, while a nucleoside is not. What they share is sensitivity to moisture in the solid state and to repeated freeze-thaw once in solution. Therefore follow the condition printed on the label and the certificate rather than applying peptide handling guidance by analogy.

Does any of the in vitro or animal data tell you what AICAR does in a person?

No, and this page makes no such claim. This page reports cell and animal measurements as cell and animal measurements. Extending them to a person is not something the cited studies support. In addition, it is not within the scope of research-use-only material. The AICAR nucleoside analog discussion on this page stays in the laboratory.

Shopping Cart

Cart (0)

Add $200.00 more to get FREE Shipping